Description: | Damage appraisal and reconstruction, monitoring for support structure damage |
Building time: | 2011 – 2012 |
Starting position Isometry of the steel construction on the reinforced concrete girder Steel construction on the reinforced concrete girder
Building project
The building is a concrete structure with prestressed beams up to a length of 15m. In distinct places the beams slided off the supports effecting a hazard of a collapse of the bearing system.
With a detailed Analysis all possible factors causing the displacement in the construction were investigated and determined, such as ground settings or thermal influences.
Based on this results an additional construction for the rehabiltation was designed and built-in.
Finally a monitoring system was installed for long term observations of the bearing system concerning its structural sustainability according to the relevant environmental influences.
Tasks: statistical analysis, monitoring, calculation, working drawings, construction supervision